TM 9-2350-311-34-1
10 Air cleaner blower motors should meet the following performance specifications:
(a)
Rated voltage: 24 Vdc.
(b) Blower load current: 7.5 amps maximum at 73°F (23°C) ambient temperature.
(c) Blower load speed: 11,500 rpm 10% at 77° F (25°C) ambient temperature. For +10% voltage, maximum
speed change of +10. For -10% voltage, maximum speed change of -10%.
VOLTAGE*
MAXIMUM AMPS
CFM INLET VACUUM GAGE READING
24
5.5
0 minutes
14.0-in. (35.6-cm) water minimum
24
6.5
40 minutes
8.0-in. (20.3-cm) water minimum
24
7.5
60 minutes
0.0-in. (0.0-mm) water minimum
*
Performance data at 72 to 82°F (22 to 28°C) ambient temperature.
NOTE
Performance curve at 24 Vdc 25 ± 8°C ambient temperature. Amps line represents
maximum values. Speed, efficiency, and watts output curves are minimum values.
PERFORMANCE CHART
NOTE
FOLLOW-ON MAINTENANCE:
Refill engine coolant system (TM 9-2350-311-10